Transformer SDK For C
8.0.2.290852-a608fcd3
|
This section of the configuration file configures the Transformer's event logging.
Type: String
Default: INFO
Specify the level at which logs are reported. This can take the following values (in order of decreasing severity/increasing verbosity):
log-level name | Description |
---|---|
CRIT | Reports critical errors that prevent the application from running. |
ERROR | Reports serious errors regarding network connections and all errors included in the CRIT log level. |
NOTIFY | Reports errors regarding data corruptions and all errors included in the ERROR and CRIT log levels. |
WARN | Reports minor errors and all errors included in the NOTIFY, ERROR and CRIT log levels. |
INFO | Reports events and information regarding normal operation, and all errors included in the WARN, NOTIFY, ERROR and CRIT log levels. |
DEBUG | Reports tracing information and all logs at a higher level. |
FINER | Reports more deatiled tracing information and all logs at a higher level. |
FINEST | Reports more deatiled tracing information and all logs at a higher level. |
Type: String
Default: CRIT
Default logging level to send log events to monitoring
Type: String
Default: ERROR
log-syslog-level specifies the level of the logs that are reported to the system log when this DataSource application is running.
You can override this setting by specifying the syslog-level option of the add-log configuration item.
On Linux system logs are written to the Linux system log. On Windows the logs are written to the Windows event log.
Type: String
Default: None
Default logging level to set for threads with thread health issues
Type: String
Default: %r/var
Default directory in which to store log files. %r is replaced by application-root, %a will be replaced by application-name.
Type: Integer
Default: 0
Maximum log file size in bytes. The log files will be cycled if they exceed the size specified here; therefore a value of 0 means log files will cycle every time they are checked.
Type: Integer
Default: 0
Log file, max number of files
Type: Integer
Default: 240
Time at which logs will cycle, in minutes from midnight.
Type: Integer
Default: 1440
Interval between cycling logs, in minutes.
Type: String
Default: .%u
Suffix for cycled logs. This is passed through strftime (refer to your UNIX manual for further information on strftime). The default of %u results in a file beiang created for each day of the week.
Type: Integer
Default: 10
Max number of log lines to retain for monitoring
Type: Integer
Default: -1
Specify buffering behaviour globally for all logs. This can be overridden on a per log basis using buffer
-1: [Default] Disable buffering for logs, write directly to disk 0: Enable line buffering. >0: Enable block buffering of configured number of bytes. Buffer is flushed to disk once it is full.
Type: String
Default: None
Specify the minimum level at which application log buffers are to be flushed. If e.g. ERROR is set as the threshold, then ERROR and CRIT logs will cause the buffer to be flushed. This feature is turned off by default meaning buffers are only flushed when they're full or the application terminates normally, for log levels and accepted values see log-level.
Type: String
Default: ALL
Category filter string
Type: Boolean
Default: FALSE
Output event logs to the terminal
add-log
As well as the global configuration options for log files, individual log files may be configured individually. This option overrides the global default for a particular logfile.
Format:
add-log name [value] maxsize [value] time [value] period [value] suffix [value] offset [value] level [value] monitor-level [value] buffer [value] buffer-flush-level [value] end-log
Type: String
Default: None
Name of log
Type: Integer
Default: -559038737
Log file max size
Type: Integer
Default: -559038737
Log file, max number of files
Type: Integer
Default: -559038737
Log Cycle Time
Type: Integer
Default: -1
Log Cycle Period
Type: String
Default: None
Log Cycle Suffix
Type: String
Default: None
Log level
Type: String
Default: None
Log level to to push log events to monitoring
Type: String
Default: None
Logging level to send log events to syslog
Type: Integer
Default: -559038737
Specify buffering for specific logs
-2: [Default] Inherit global settings -1: Disable buffering for logs, write directly to disk 0: Enable line buffering. >0: Enable block buffering of configured number of bytes
Type: String
Default: INHERIT
Override the global log-buffer-flush-level setting for specific logs.
The default value of this option is "INHERIT" indicating that the global setting shall be inherited.
Type: String
Default: None
Category filter string